OPERATING INSTRUCTIONSR88-OUTPUTMIDI-CONTROLLEDRELAY ARRAYPROFESSIONALSERIESMIDI Solutions
10ContactRatingsReplacementFuseContactRating:Maximum10WattsSwitchingVoltage:Maximum200VoltsDCSwitchingCurrent:Maximum0.5AmpsDC0.5A 3AG
MIDI Solutions R8 Operating Instructions M426-1002012 MIDI Solutions Inc. All rights reserved.MIDI Solutions Inc.PO Box 3010Vancouver, BC CanadaV6B 3X
ThankyouforpurchasingtheMIDISolutionsR88-outputMIDI-controlledRelayArray.TheMIDISolutionsR8containseightMIDI-controlledrelaysthate
4TheR8isprogrammedbysendingitMIDISystemExclusiveprogrammingcommandsfromacomputerwithaMIDIinterface.Thesecommandsaredescribedont
NOTEToprogramtheR8torespondtoaNotemessage,senditthefollowingSystemExclusiveprogrammingcommand:( isoptional)AllbytesmustbeinHexa
CONTROLCHANGEToprogramtheR8torespondtoaControlChangemessage,senditthefollowingSystemExclusiveprogrammingcommand:( and areoptional)A
7PROGRAMCHANGESTART/STOP/CONTINUEToprogramtheR8torespondtoProgramChangemessages,senditthefollowingSystemExclusiveprogrammingcommand:(
SYSTEMEXCLUSIVEToprogramtheR8toCLOSEuponreceivingaSystemExclusivemessage,senditthefollowingprogrammingcommands:followedby ( isoptio
Thevalue intheprogrammingcommandsisassignedaccordingtothefollowingtable:cc16 ALLMIDICHANNELTABLEMIDICONTROLCHANGETABLEDecimal012345678